Permit: T10PL01283

Parcel: 141140870


Addresses:

8000 S CARBURY WY

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/24/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
08/18/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A SEDIMENT TRAP AT GAS ENTRY TO WATER HEATER
2) PROVIDE APPROVED VENT AND CONNECTION TO DRAFT HOOD
3) PROVIDE RIGID FULL SIZE T & P DRAIN GRAVITY TO DAYLIGHT FOR WATER HEATER
4) SECURE ALL ANGLE STOPS
5) WATER DISTRIBUTION IS COVERED WITHOUT INSPECTION, EXPOSE PIPING FOR INSPECTION
6) PROVIDE CORRECT BACKFLOW PROTECTION FOR POOL FILL
7) HOSE BIBS TO HAVE VACUUM BREAKERS WITH TAMPER SCREWS BROKEN OFF