Permit: T10PL01204

Parcel: 126133990


Addresses:

4609 E 20TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/02/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
07/30/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PIPING CANNOT BE ON FLOOR
2) WATER HEATER TEMPERATURE AND PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT TERMINATING 90 DEGREE DOWN WITH FULL SIZE 3/4" PIPING AND BE FUNCTIONAL VALVE
3) VENT CONNECTORS TO BE CONNECTED IN DIRECTION OF FLOW WITH FURNACE AS STRAIGHT RUN THRU WATER HEATER AS BRANCH VENT
4) SUPPORT PIPING AT WATER HEATER FURNACE