Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/16/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) FURNACE REQUIRES APPROVED SINGLE OF DBL WALL FULL SIZE 4" VENT FROM FURNACE OUTLET TO DBL WALL AT CEILING. PROVIDE MINIMUM 3 FASTENERS AT JOINTS IN USING SINGLE WALL VENT CONNECTOR PIPING |
|
| 08/10/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE APPROVED CSA GAS APPROVED VALVES AND FLEXES 2) RUN T & P FOR WATER HEATER TO DAYLIGHT 6" TO 24" GROUND 3) PROVIDE 1" CLEARANCE AROUND FLUE VENT FOR WATER HEATER AT CEILING 4) PROVIDE WORKING GAUGE AND REPAIR ALL LEAKS IN 1/10 PSI INCREMENTATION |
|
| 08/02/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/29/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |