Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 08/12/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/29/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) WALK THRU WITH HOMEOWNER |
|
| 07/27/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE CSA GAS APPROVED VALVES FOR STOVE, WATER HEATER, FURNACE AND GAS FLEXES AT ALL 2) PROVIDE APPROVED INSTALL OF FLUE VENT FOR WATER HEATER AND FURNACE-EXTEND 3' ABOVE COOLER WITH TYPE B FLUE VENT AND CAP 3) PROVIDE APPROVED INSTALL FOR T & P FROM WAER HEATER. PROVIDE FULLSIZE PIPING TO DAYLIGHT, NO FLEX 4) COMPLETE LIST CALL FOR FINAL AND GAS CARD 5) PSI TEST ON GAS PIPING OK |