Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/12/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEAK ON T & P DRAIN LINE NOTE: A NEW WATER HEATER REQUIRES A NEW GAS FLEX |
|
| 07/09/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NOBODY ANSWERED DOOR |
|
| 07/07/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) FINISH WATER HEATER INSTALLATION 2) RUN T & P RELIEF DRAIN 3) REMOVE METAL BACK TAPE FROM JOINTS AND MAKE UP CORRECTLY 4) CLEARANCES FROM COMBUSTION ? 5) VENT CONNECTOR MAY NOT PASS THRU CEILING 6) CONTINUED NOT READYS WILL RESULT IN A REINSPECTION FEE |
|
| 07/06/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) OK TO COVER WALLS 2) RECALL 03090 AFTER WATER HEATER IS RESET |