Permit: T10PL00960

Parcel: 136345060


Addresses:

7409 E VANCOUVER DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/24/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
06/23/2010 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
06/21/2010 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
1) TEST FROM METER TO BLDG SHUT OFF VALVE ONLY OK
2) RETEST SYSTEM IN IT'S ENTIRETY, TO APPLIANCES
3) TRY TO PROVIDE A PIPING ARRANGEMENT THAT WILL MAKE WATER HEATER REMOVAL AVAILABLE WITHOUT DISASSEMBLY OF GAS PIPING
4) SECURE GAS PIPING AT METER AND AT FURNACE/ WATER HEATER AREA
5) PROVIDE BONDING OF BLDG GAS PIPING