Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10PL00886
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) WATER HEATER OK |
|
06/04/2010 | PLUMBING - FINAL | Cancelled | CANCELLED PER BRIAN OF AMERWISE PLUMBING #762-9077 | |
06/04/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE MINIMUM 1" OF CLEARANCE AROUND B-VENT AT ROOF PENETRATION 2) INSTALL WATER HEATER SOV UP STREAM OF FLEX CONNECTOR 3) PROVIDE ONE FLEX CONNECTOR OF PROPER LENGTH 4) FLEXES ARE NOT TO BE LINED TOGETHER 5) NOTE: PVC IS NOT APPROVED FOR USE INSIDE HOME AND A PERMIT IS REQUIRED BY LAW FOR A WATER REPIPE |