Permit: T10PL00886

Parcel: 127033670


Addresses:

5637 E 3RD ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T10PL00886

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/10/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
1) WATER HEATER OK
06/04/2010 PLUMBING - FINAL Cancelled CANCELLED PER BRIAN OF AMERWISE PLUMBING #762-9077
06/04/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE MINIMUM 1" OF CLEARANCE AROUND B-VENT AT ROOF PENETRATION
2) INSTALL WATER HEATER SOV UP STREAM OF FLEX CONNECTOR
3) PROVIDE ONE FLEX CONNECTOR OF PROPER LENGTH
4) FLEXES ARE NOT TO BE LINED TOGETHER
5) NOTE: PVC IS NOT APPROVED FOR USE INSIDE HOME AND A PERMIT IS REQUIRED BY LAW FOR A WATER REPIPE