Inspection Status: Passed
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 02/07/2011 |
COT - RSPL - Plumbing Final |
RLEDONNE |
Approved |
Entered by RLEDONNE - IVRS - Inspection :* |
| 06/03/2010 |
COT - RSPL - Plumbing Final |
RRICH |
Denied |
Entered by RRICH - IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SEDIMENT TRAP AT GAS ENTRY
2) REMOVE ALL TAPE FROM VENT CONNECTORS AND PROVIDE FASTENERS
3) PROVIDE APPROVED VENT TRANSITION FROM CONNECTOR TO THRU CEILING OR PROVIDE DBL WALL THRU CEILING AND ROOF WITH APPROVED DBL WALL VENT CAP
4) CLEAN COMBUSTION AIR VENT SCREEN |