Permit: T10PL00818

Parcel: 128141220


Addresses:

914 S MAGNOLIA AV

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/26/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SOUTH FURNACE: PROVIDE 4" DBL WALL VENT THRU ROOF TO 3' ABOVE TOP OF COOLER INTAKE WITH 4" APPROVED VENT CAP
2) CAP OLD GAS PIPING INSIDE BLDG
3) PROVIDE BONDING OF BLDG GAS SYSTEM
4) PROVIDE RIDGID PIPE FOR TEMPERATURE AND PRESSURE RELIEF DRAIN WITH 1" AIR GAP AND TIGHTEN UNION (NO FLEX FOR WATER HEATER AND T & P DRAIN)
5) SEAL 2" PIPE PENETRATION INTO EXTERIOR SOFFIT (FOR BUG PROOF)
6) SEAL ROOF FLASHING TO DBL WALL VENTING WEATHER TIGHT
7) CLAMP 2" PIPE TO BLOCK ON ROOF AND SECURE ALL PIPING IN ATTIC