Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) GAS CARD AT METER |
|
| 05/25/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST TO HOLD WITHOUT NO LOSS OF PRESSURE FOR 15 MINUTES 2) PROVIDE CORRECT COMBUSTION AIR FOR WATER HEATER |
|
| 05/19/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEST TO BE ON ENTIRE GAS PIPING SYSTEM THRU LOG LIGHTER VALVE INTO HEARTH OF FIREPLACE 2) PROVIDE APPROVED GAS SHUT OFF VALVES FOR FURNACE AND WATER HEATER 3) PROVIDE BONDING OF BLDG GAS PIPING SYSTEM 4) SUPPORT GAS PIPING AT EXTERIOR AND INTERIOR 5) WATE HEATER TEMPERATURE AND PRESSURE RELIEF TO GRAVITY DRAIN TO DAYLIGHT 6) PROVIDE COMBUSTION AIR FOR WATER HEATER 7) SEAL PIPE ENTRY INTO BLDG 8) REMOVE METAL PANEL FOR PIPING INSPECTION AT WATER HEATER 9) YOUR PLAN DOES NOT MATCH THIS BLDG SYSTEM |
|
| 05/17/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ACCESS AT 11:15 |