Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/11/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) OK TO COVER YARD PIPING AND ALL AREAS EXCEPT MASTER BATHROOM LISTED BELOW 2) SEAL PIPE PENETRATION INTO BLDG 3) PROVIDE CORRECT BACKFLOW PROTECTION FOR LANDSCAPING SUPPLYW ITH VALVE DOWN STREAM OF ATMOSPHERIC BACKFLOW PREVENTOR 4) SECURE ANGLE STOPS IN MASTER BATHROOM LAVS AND STOOL 5) PROVIDE A MECHANICAL PERMIT FOR NEW SPLIT SYSTEM A/C UNIT 6) PLEASE CALL IN BOTH INSPECTIONS FOR SAME DAY 7) IDENTIFY YOUR NEW A/C CIRCUIT IN ELECTRICAL PANEL 8) 20 AMP FUSE IS MAX LISTED ON NEW A/C UNIT LISTING PLATE |