Permit: T10PL00732

Parcel: 135081160


Addresses:

7309 E 28TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/12/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
05/11/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE FUNCTIONAL DBL WALL VENT THRU CEILING AND ROOF WITH APPROVED VENT CAP EXTENDING MINIMUM 3' ABOVE COMBUSTION AIR INTAKE. NO TAPE ON VENT CONNECTORS OR VENT PIPING. FASTENERS ARE REQUIRED ON VENT CONNECTOR
2) PLUG PAN DRAIN ON WATER HEATER
3) PROVIDE 1" AIR GAP FOR T & P DRAIN PIPE AND TOP OF DRIP PAN