Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/25/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/17/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/17/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* ADDRESS 2801 IS WRONG. SHOULD BE 2401. THIS MUST BE CHANGED. REMOVE TRAP FROM T & P DRAIN FROM WATER HEATER #1 TERMINATE T& P FROM WATER HEATER #2 TO OUTDOORS WITH DOWNBILL SLOPE. REMOVE SINGLE WALL ELBOW FROM VENT PIPE AND USE DOUBLE WALL . SCREW SINGLE WALL VENT TO DRAFT DIVERTER OK TO BACKFILL TRENCH |
|
| 05/14/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE T & P DRAINS TO DAYLIGHT 2) GAS FLEX TO WATER HEATER NOT TO EXCEED 3' IN LENGTH 3) PROVIDE A SEDIMENT TRAP AT WATER HEATERS AND FURNACES 4) 3/8" I.D. X 18" GAS FLEX TO FURNACE NOT ADEQUATE FOR 115,000 BTU 5) WATER HEATER IN GARAGE PROVIDE 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR. EXTEND DBL WALL INTO ROOM 6) 1/2" GAS LINE TO FURNACE NOT ADEQUATE. USE 3/4" 7) PROVIDE A 15 POUND PRESSURE GAUGE |