Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2010 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 05/25/2010 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE MIN OF 18" OF COVER FOR UNDERGROUND GAS PIPING IN DRIVE WAY 2) PROVIDE COMBUSTION AIR FOR WATER HEATER ROOM 3) PROVIDE NEW FLEXS FOR WATER HEATER AND FURNACE |