| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/05/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/03/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE 1" CLEARNANCE AROUND FLUE VENT THRU CEILING FOR WATER HEATER 2) PROVIDE MINIMUM 10 POUND TEST ON ALL GAS PIPING 3) PROVIDE PIPING FOR T & P AT WATER HEATER 6" TO 24" OF GROUND 4) PROVIDE ROOF JACK FOR GAS PIPING GOING THRU ROOF 5) ADD SUPPORTS AND CLAMPS ON ROOF AND DOWN WALL FOR ALL GAS PIPING |
|
| 04/28/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER OWNER |