Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 04/16/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) LAW REQUIRES BACKFLOW PROTECTION FROM POSSIBLE CONTAMINATION FOR PUBLIC HEALTH. PERMANENTLY CAP ABANDON IRR CONN OR INSTALL DEVICE 2) ISOLATE PEX TOUCHING CAST IRON VENT AND GALVANIZED PIPING |
|
| 04/14/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER NEEDS TO BE ON FOR INSPECTION 2) APPROVED BACFLOW PROTECTION REQUIRED FOR IRRIGATION SUPPLY 3) SECURE TUBING IN WALLS 4) SEAL OLD PIPES 5) SECURE DW 6) NEW WATER HEATER REQUIRES PROPER T & P TERMINATION AND VENT CORRECTION 7) PROVIDE ACCESS TO ATTIC |
|
| 04/12/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NOBODY HOME |