Permit: T10PL00465

Parcel: 136161320


Addresses:

8555 E SHASTA DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/26/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
03/24/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) REMOVE ALL TAPE FROM WATER HEATER/FURNACE VENT PIPING, PROVIDE APPROVED WYE FITTING, AND 3 FASTENERS AT EACH VENT JOINT
2) WATER HEATER TEMPERATURE AND PRESSURE RELIEF SHALL GRAVITY DRAIN
3) BONDING TO BE TO COLD WATER SIDE
4) EXTEND WATER HEATER/FURNACE VENT WITH FULL SIZE DBL WALL VENT PIPING 3' ABOVE TOP OF COOLER INTAKE IF WITHIN 10' AND REINSTALL APPROVED VENT CAP