Permit: T10PL00297

Parcel: 107111730


Addresses:

220 W BLACKLIDGE DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/23/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
07/20/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
07/13/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) WATER HEATER ON WOOD PLATFORM REQUIRES A DRIP PAN. INSTALL WATER SOV.
2) WATER HEATER VENT MUST RISE VERTICALLY MINIMUM 5' WITH TYPE B THRU ROOF WITH FLASHING
3) CHECK WATER HEATER T & P VALVE FOR OPERATION, TERMINATE 24" ABOVE GROUND WITHOUT THREADS
4) A CITY APPROVED PIPING DIAGRAM IS REQUIRED FOR A REPIPE
5) PROVIDE FLASHINGS AT ROOF PENETRATIONS, PROPER PIPING SUPPORTS WITH CLAMPS AND ELECTRICAL BONDING OF GAS SYSTEM
NOTE: NEW HEAT PUMP WILL REQUIRE A PERMIT AT TIME OF INSTALLATION, ALSO PVC IS NOT APPROVED AND A WATER REPIPE REQUIRES A PERMIT