Inspection History Details
Inspection Status: Partial Approval
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/27/2010 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) TYPE B VENT REQUIRED ABOVE ROOF 2) EXTEND BOTH B VENTS WITHIN 10' OF COOLER 3) MOVE BONDING CLAMP TO UNCOATED PIPE 4) SECURE ALL JOINTS ON WATER HEATER VENT |
|
| 04/26/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/09/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) APPROVED COATED GAS PIPING REQUIRED BELOW GRADE WITH FITTINGS PRIMED AND WRAPPED, 12" MIN COVER REQUIRED 2) EXTERIOR HOUSE SHUT OFF VALVE REQUIRED 3) CORRECT THE MAKE UP OF THE VENT 4) CONNECTOR TO B-VENT CONNECTION AT FURNACE 5) SEDIMENT TRAPS REQUIRED 6) CORRECT WH VENT CONNECTOR. SECURE EACH JOINT WITH GALV SHEET METAL SCREWS 7) PROVIDE CORRECT VENT TERMINATION ABOVE COOLER 8) INSTALL A METAL WH PAN, COMPLETE AND FOLLOW PETITION OF APPEAL FORM FOR WH RELIEF DRAIN 9) 10 PSI TEDST REQUIRED. PROVIDE ROOF ACCESS AND APPROVED SUPPORTS 10) SEE GAS HAND OUT AND PETITION OF APPEAL FORM |