Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2010 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/18/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 02/17/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) YARD LINE SHALL BE A MINIMUM OF 18", TEST OK 2006 UPC APP E SECTION E36 2) PROVIDE A MOBILE HOME FLEX AND TEST ENTIRE SYSTEM 3) SUPPORT PIPING AT HOUSE CONNECTION 4) TEST/INSPECT T & P RELIEF VALVE FOR PROPER OPERATION AND REPLACE AS NEEDED 5) EXTEND WATER HEATER VENT ABOVE COOLER |
|
| 02/17/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) YARD LINE ONLY |