Permit: T10PL00108

Parcel: 135101690

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
01/27/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
01/26/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE 3/4" PIPING TO F.A.U. PER PIPING DIAGRAM
2) PROVIDE PROPER SIZE FLEX TO F.A.U. 3/8" ID DOES NOT CARRY 120,000 BTU
01/25/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) 12 PSI TEST IS OK-LEFT GAS CARD
2) EXTEND THE WATER HEATER AND FURNACE VENTS MINIMUM 3' ABOVE COMBUSTION AIR INTAKE ON ROOF
3) USE DBL WALL VENT PIPE OF THE SAME MANUFACTURER AS THE EXISTING VENT-AMERIVENT