Permit: T10PL00028

Parcel: 115202310


Addresses:

1952 W ELM ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/13/2010 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
01/12/2010 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPORT AND SECURE CSST ABOVE ROOF, AND AT FURNACE VALVE
2) PROVIDE FULL SIZED PIPING TO FIRST TEE AT HOUSE EXTERIOR
3) SHUT OFF VALVE REQUIRED WITH REMOTE METER LOCATION
4) PROVIDE A VENT FOR WATER HEATER TYPE B
5) PROVIDE AN OPERATIONAL T & P VALVE WITH PROPER TERMINATION