Permit: T10PL00008

Parcel: 11103012A

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/02/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) MET WITH OWNER AND JIM MILITELLO ON SITE
2) GAS UTILITY CLEARANCE APPROVED STRICTLY FOR THE PURPOSE OF FACILITATING SOUTHWEST GAS WORK
3) THERE WILL BE NO COOKING OF ANY KIND UNTIL PREVIOUSLY IDENTIFIED ISSUES WITH HOODS ARE CORRECTED PHYSICALLY WITH WORK DESCRIBED IN A NEW MECHANICAL PERMIT-OR-BLDG OFFICIAL DETERMINATION IS MADE IN CONSIDERATION OF A PREVIOUSLY APPROVED C OF O (T04OT00267)
4) OWNERS UNDERSTAND THAT A CURRENT C OF O IN PROGRESS NEEDS TO BE COMPLETED AND APPROVED BEFORE OCCUPANCY
01/29/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SPOKE WITH BLDG OWNER, TOLD HIM I COULD NOT LEAVE A GAS CARD FOR THE TYPE I EQUIPMENT WITH AN EXHAUST FAN TERMINATED NEXT TO A WOOD WALL AND UNDER AN EAVE ON THE ROOF. I OFFERED TO MEET AT THE JOB SITE TO DISCUSS ISSUES. RECOMENDED HE TALK TO MY SUPERVISOR, JASON JAWORSKY, FOR FURTHER DIRECTION. THERE IS NO HISTORY OF ANY HOODS OR TYPE I EQUIPMENT EVER INSTALLED OR INSPECTED AT THIS BUSINESS. THE OWNER HUNG UP ON ME.
01/21/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) GAS LINE INSTALLATION AND PRESSURE TEST OK
2) CANNOT LEAVE A GAS CARD UNTIL APPLIANCES ARE IN PLACE, HOWEVER THE KITCHEN EXHAUST EQUIPMENT WILL NOT PASS INSPECTION
3) THE COMMERCIAL OVEN REQUIRES A TYPE I EXHAUST SYSTEM
4) THE SMALL HOOD CANNOT HAVE A FAN TERMINATED NEX TO A WALL AND UNDER AN EAVE
5) THE OTHER EXHAUST FAN MUST BE ON A VENTILATED CURB
01/19/2010 PLUMBING - FINAL Partial Approval IVRS - Inspection :*