Permit: T10OT00835

Parcel: 118121000


Addresses:

1317 S 6TH AV #139

Inspection Status: Approved

Inspection History: CERTIFICATE OF OCCUPANCY

Date Description Inspector Results Comments
11/24/2010 CERTIFICATE OF OCCUPANCY Approved IVRS - Inspection :*
11/23/2010 CERTIFICATE OF OCCUPANCY Partial Approval IVRS - Inspection :*
1) #7 NOT DONE CORRECTLY OR REMOVE
07/01/2010 CERTIFICATE OF OCCUPANCY Not ready for Inspection IVRS - Inspection :*
1) INSTALL CORRECT LIGHT FIXTURE IN RESTROOM
2) SECURE CONDUIT BY SINK AND OUTLET BOXES
3) NEED EXHAUST FAN TO OUTSIDE AND SOLID DOOR WITH PRIVACY KNOB
4) FLEX FROM WATER HEATER TO BOX NEEDS TO BE CONNECTED CORRECTLY
5) LOFT BATHROOM NEED VENTILATION
6) LABEL ALL BREAKERS IN PANEL
7) STAIR TREADS 11" MIN. RISER 4" TO 7"
8) INSTALL BACKFLOW PREVENTER ON HOSE BIB
9) HANDRAIL 34" TO 36" OFF TREAD
10) REPLACE BROKEN GLASS TEMPERED WITHIN 2' FROM DOOR