Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
12/22/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
12/16/2010 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE A PROTECTIVE COATING ON ALL EXPOSED ARMAFLEX
2) LOW VOLTAGE WIRING MUST BE PRTOTECTED FROM DAMAGE
3) DO NOT HAVE PVC WITHIN 6" OF VENT CONNECTOR. USE COPPER IF NECESSARY
4) CONNECT THE OVERFLOW SENSOR ON PUMP. WHERE IS THE BRUSH FOR THE CONDENSATE TRAP ?
5) NO ACCESS TO ROOF. WHERE IS CONDENSATE TERMINATED ? PROVIDE ACCESS