Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/21/2011 | MECHANICAL - FINAL | Approved | STRUCTURAL IS OK FOR EXISTING SPAN EVEN WITHOUT TRUSS CONFIGURATION. | |
| 12/30/2010 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) ITEM 3 DATED 12/23/10 STILL NOT CORRECTED, ALL OTHER ITEMS OK |
|
| 12/23/2010 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) PROVIDE AN APPROVED GAS SHUT OFF VALVE AT FURNACE 2) FURNACE VENT CONNECTOR 1ST FITTING NOT CRIMPED OR GOING SAME DIRECTION AS FLOW. PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTION 3) PROVIDE THE REQUIRED STRUCTURAL DRAWING FOR NEW A/C ON THE ROOF 4) PROVIDE PROTECTIVE COATING ON EXPOSED ARMAFLEX 5) SUPPORT ELECTRIC CONDUIT 6) TERMINATE CONDENSATE TO AN APPROVED LOCATION |