Permit: T10ME00289

Parcel: 11306171B


Addresses:

3219 N WILSON AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/25/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/24/2010 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) ITEMS 1, 3 & 4 DATED 5/21/10 STILL NEED TO BE CORRECTED
05/21/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE ROMEX CONNECTOR WHEN ENTERING CABINET WITH WIRING
2) ALL PVC JOINTS ARE TO BE PRIMED, ALL PRIMER IS TO BE PURPLE IN COLOR
3) PROVIDE P-TRAP AND VENT AT COIL PER INSTALL INSTRUCTIONS
4) PROVIDE MEANS OF SECONDARY DRAIN
5) SEAL AND DUCT IN MECH. CLOSET
6) FLUE PIPE IS RUN BACKWARDS AT REDUCER
7) REMOVE WHITE WIRE FROM LINE VOLTAGE TO C.U. PROVIDE APPROVED COLOR CODE. PROVIDE FACE PLATE IN DISCONNECT BOX
8) PROTECT WIRING TO C.U. IN SHED