Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/06/2011 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANY FURTHER FAILURES WILL RESULT IN A REFEE ATTACHED TO THIS PERMIT |
|
| 05/05/2011 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/03/2011 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) FLUE PIPE NOT PROPERLY INSTALLED 2) PROVIDE MINIMUM 6" CLEARANCE FROM SINGLE WALL FLUE PIPE TO COMBUSTIBLE MATERIALS 3) ALL PVC PIPE AND FITTINGS ARE TO HAVE PRIMER AT ALL POINTS RECEIVING GLUE, PRIMER IS TO BE PURPLE IN COLOR. PRIMERS IS TO BE APPLIED PRIOR TO GLUE 4) PROVIDE SEDIMENT TRAP AT GAS PIPING TO UNIT 5) PROVIDE ACCESS TO ROOF FOR COMPLETE INSPECTION |