Permit: T10ME00173

Parcel: 111063660


Addresses:

2842 N FLANWILL BL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/26/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
03/31/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE A BUSHING IN THE ELECTRIC DISCONNECT
2) PROVIDE THE REQUIRED GFI SERVICE RECEPT ON ROOF WITH A BUBBLE TYPE COVER
3) TERMINATE CONDENSATE TO WITHIN 6" OF THE GROUND WITH AN ELBOW AND A NIPPLE
4) PROVIDE MINIMUM R8 DUCT IN EXPOSE DUCT ON THE ROOF
5) GAS PIPE CANNOT BE INCREASED FROM 1/2" TO 3/4'