Permit: T10ME00034

Parcel: 131070930


Addresses:

6121 E 25TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
02/05/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
01/29/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TERMINATE CONDENSATE WITHIN 6" OF THE GROUND
2) PAINT EXPOSED PVC WITH LATEX PAINT
3) RELOCATE GAS LINE FROM BLOCKING ACCESS AND REMOVED OF COMPRESSOR
4) NEED TO SEE ALL NEW GAS PIPING
5) PROVIDE A PRESSURE TEST ON ALL NEW GAS PIPING
6) PROPERLY SUPPORT GAS PIPE ON ROOF AFTER RELOCATING
7) PROVIDE A BUSING IN ELECTRIC DISCONNECT-NOT TAPE
8) SECURE THE ANGLE IRON STAND TO THE STRUCTURE
9) PROVIDE THE REQUIRED GFI SERVICE RECEPT ON THE ROOF
10) PROVIDE THE REQUIRED STRUCTURAL DRAWING AND APPROVAL FOR NEW EQUIPMENT ON ROOF