Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T10ME00018
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2010 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE |
|
01/21/2010 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) THE SERVICE RECEPT ON THE ROOF DOES NOT HAVE POWER |
|
01/12/2010 | MECHANICAL - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CONDENSATE CANNOT TERMINATE INTO A SEWER VENT |