Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T10ME00011

Parcel: 119421350


Addresses:

4855 S ALBACETE AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/22/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
01/21/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WORK NOT COMPLETED, NEXT FAILED INSPECTION WILL RESULT IN A REFEE ASSESSED TO THIS PERMIT
01/14/2010 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SUPPLY AND RETURN DUCT IN GARAGE TO BE INSULATED
2) PROVIDE SECONDARY DRAIN ON A/C COIL
3) ALL PVC JOINTS TO BE PRIMED PRIOR TO GLUE PRIMER IS TO BE PURPLE IN COLOR PER U.P.C.
4) REMOVE ALL METAL TAPE FROM FLUE PIPE
5) PROVIDE PAN UNDER WATER HEATER
6) PROVIDE WEATHER RESISTANT COATING ON FOAM INSULATION ON EXTERIOR OF BLDG