Case: T10FR02681

Parcel: 13414020E


Addresses:

1102 S PANTANO RD


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T10FR02681

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2010 INSP - FULL Approved 1. _____ 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits:
" Places of detention or restraint.
" In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:
2.1. The locking device is readily distinguishable as locked,
2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background,
2.3. The use of the key-operated locking device is revokable by the fire code official for due cause.

2. _____ 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used:
-PLACE BLAMKS IN THE ELECTRICAL PANEL WHERE THE BREAKERS ARE MISSING