Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/24/2010 | INSP - FULL | Approved | abated | |
| 08/09/2010 | INSP - FULL | Correction Required | 1. _____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied - Provide back up power supply for all required exit illumination ON TWO FRONT EXIT SIGNS 2. _____ 605.5 Extension Cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. - TWO EACH IN REAR ROOM 3. _____ 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. - FORNT EAST EXIT - REAR EXIT DOOR |