Case: T10FR01635

Parcel: 13824023H


Addresses:

2011 W VALENCIA RD


Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T10FR01635

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Violation

Date Description Inspector Results Comments
08/06/2010 VIOL - MEANS OF EGRESS Violation 1003.6 - Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.

_____ Clear exit path, and maintain it this way.
08/06/2010 VIOL - MEANS OF EGRESS Violation 1008.1.2 Door swing. Egress doors shall be side-hinged swinging.
Doors shall swing in the direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy.