Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T10FR01246
Inspection Description - INSP - FULL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/16/2010 | INSP - FULL | Approved | abated | |
| 06/23/2010 | INSP - FULL | Correction Required | 1. _____ 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits: " Places of detention or restraint. " In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in churches, the main exterior door or doors are permitted to be equipped with key-operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked, 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background, 2.3. The use of the key-operated locking device is revokable by the fire code official for due cause. - REAR EXIT MUSR BE PROVIDED WITH A THUMB-LATCH - FRONT EXIT NEEDS A SIGN STATING, " THERE DOORS TO REMAIN UNLOCKED WHILE THE BUILDIG IS OCCUPIED" 2. _____ 3003.5 Security. Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgment and against access by unauthorized personnel in accordance with Sections 3003.3.1 through 3003.3.3. 3. _____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied - 2 EACH IN EAST DINING ROOM 4. _____ 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. The face of an exit sign illuminated from an external source, shall have an intensity of not less than foot-candles (54 lux). Internally illuminated signs shall provide equivalent luminance and be listed for the purpose. -EAST EXIT 5. _______ 904.11.1 Manual system operation. A manual actuation device shall be located at or near a means of egress from the cooking area a minimum of 10 feet (3048 mm) and a maximum of 20 feet (6096 mm) from the kitchen exhaust system. The manual actuation device shall be installed not more than 48 inches (1200 mm) nor less than 42 inches (1067 mm) above the floor and shall clearly identify the hazard protected. The manual actuation shall require a maximum force of 40 pounds (178 N) and a maximum movement of 14 inches (356 mm) to actuate the fire suppression system - PROVIDE COVERAGE OVER THE PITCO THERMALIZER FRESHSIDE GRILLE COOKER AS PER MANUFACTURES INSTRUCTIONS NOTE; i WILL CHECK THE EAST PANIC HARDWARE UPON RE-INSPECTION. PLEASE FIND TEH KEYS TO THE ALARM. |