Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T10FR01231

Parcel: 13634796A


Addresses:

3711 S KOLB RD


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T10FR01231

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
08/09/2010 INSP - FULL Approved
06/21/2010 INSP - FULL Correction Required 1. _____ 605.5 Extension Cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances.
-BEHIND DISHWATER

2. _____ 605.4 Multiplug adapters. Multiplug adaptors, such as cube adaptors, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited.
- BEHIND MICROWAVE

3. _____ 2703.5 Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official.
- PROVIDE SIGNS ON FRONT OF BUILDING AND IN THESTRAGE AREA STATING "FLAMMABLE GAS"