Case: T10FR01041

Parcel: 13510150R

Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T10FR01041

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
06/09/2010 INSP - FULL Approved
05/27/2010 INSP - FULL Correction Required 1. _____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied
- ALL THREE EXITS SIGNS

2. _____ 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits:
- 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background,

- The main exit shall have the proper sign. All other exits shall be provied with a thumb-lacth device

3. _____ 605.4.2 Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle:
- Remove the powerstrips in a series behind the TV's near the North wall.

4. _____ 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed:
- Fire extinguishers shall be serviced allually. Last 1997

5. _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes:
- East Wall
- West wall