Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
Case Number - T10FR01014
Inspection Description - VIOL - BUILDING SVCS & SYSTEMS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/16/2010 | VIOL - BUILDING SVCS & SYSTEMS | Approved | ||
05/21/2010 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Extension cords: TFC2006/ 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ Remove or replace with approved fused power strip. |
|
05/21/2010 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Open space in electrical panel: TFC2006 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. _____Place an approved "blank" in the space. [boiler room] |
|
05/21/2010 | VIOL - BUILDING SVCS & SYSTEMS | Violation | Multiplug adapters: TFC2006/ 605.4 Multiplug adapters. Multiplug adapters, such as cube adapters, unfused plug strips or any other device not complying with the ICC Electrical Code shall be prohibited. ______Remove noncomplying devices. [office, shop, laundry- behind dryers] |