Case: T10FR00659

Parcel: 13316027E

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
03/25/2010 VIOL - MEANS OF EGRESS Correction Required 1008.1.8.1 Hardware.
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate.

1008.1.8.4 Bolt locks.
Manually operated flush bolts or surface bolts are not permitted.

_____ Remove the slide bolt from the ---- egress door, as bolt lock of any kind are not permitted
03/25/2010 VIOL - MEANS OF EGRESS Correction Required 1021.2 Width.
The width of exit passageways shall be determined as specified in Section 1005.1 but such width shall not be less than 44 inches (1118 mm), except that exit passageways serving an occupant load of less than 50 shall not be less than 36 inches (914 mm) in width. The required width of exit passageways shall be unobstructed.

_____Maintain minimum aisle width