Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FULL
Case Number - T10FR00387
Inspection Description - INSP - FULL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/09/2010 | INSP - FULL | Approved | ||
02/22/2010 | INSP - FULL | Correction Required | FIRE INSPECTION REPORT Chicago Store ATTN: Billy Sutton 130 E. Congress Tucson, AZ. 85701 Dear Mr. Sutton The Tucson Fire Department has conducted a fire safety inspection at the above stated business on February 22, 2010. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2006 International Fire Code (with modifications). A Re-inspection will be performed on or about March 8, 2010. Notice of Violations: 1. _____ 1008.1.8.3 # 2.2Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exits: -A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25mm)high on a contrasting background. Required Action: Provide the proper signage on the main front entrance 2. _____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied Required Action: All emergency back-up lighting shall operate: - SE corner of first floor - SW (top of stairs) - Fix broken exit sign hanging from wiring in basement - Emergency light North Mezzanine (Middle) 3. _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Required Action: Abate all electrical hazards - Place blanks in the electrical panel "B" in the brazing areas near the sink - Replace missing electrical outlet coves across from the bathroom (SW first floor) - Repair electrical wiring the "Flute room." Currently the wiring does not terminate in a box and the light switch has Romex with wire nuts exposed and electrical tape) - Replace missing J-box cover in the basement (East Wall) 4. _____ 2703.5.1 Markings. Individual containers, cartons or packages shall be conspicuously marked or labeled in an approved manner. Rooms or cabinets containing compressed gases shall be conspicuously labeled: Required Action: Properly label and store your container of vinegar. - There is approx. 30 container used as a dip tank. Properly label the container as to the contents 5. _____ 315.2.4 Attic, under-floor and concealed spaces. Attic, under-floor and concealed spaces used for storage of combustible materials shall be protected on the storage side as required for 1-hour fire-resistance-rated construction. Openings shall be protected by assemblies that are self-closing and are of noncombustible construction or solid wood core not less than 1.75 inches (44.5 mm) in thickness. Required Action: Do not store combustibles under the exit stairway from South Mezzanine. 6. ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. |