Case: T10FR00139

Parcel: 141153540

Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T10FR00139

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2010 INSP - FULL Approved abated
02/09/2010 INSP - FULL Correction Required re check 2/15/2010

1. extinguisher
2. power strips in series
01/25/2010 INSP - FULL Correction Required 1. _____ 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes.
- SOUTH WALL

2. _____ 605.4.1 Power tap design. Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, and shall be listed.
-FRONT COUNTER

_____ 906.2 General requirements. Fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10.
-SERVICE FIRE EXTINGUISHER

_____ 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, back-up power shall be supplied
- back up EMERGENCY LIGHTS SHALL OPERATE
01/25/2010 INSP - FULL Correction Required