Inspection Status: Approved
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
Case Number - T10FR00086
Inspection Description - VIOL - BUILDING SVCS & SYSTEMS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2010 | VIOL - BUILDING SVCS & SYSTEMS | Approved | ALL VIOLATIONS ABATED. | |
01/15/2010 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. 1.___ ELECTRICAL OUTLET, LIGHT SWITCHES NEED APPROVED COVERS NEAR REAR EXIT OUT OF BUILDING. |
|
01/15/2010 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. 1.___ STEREO ON BAKERS RACK NEEDS TO BE PLUGGED INTO AN APPROVED MULTIPLUG ADAPTER WITH GFI. |