Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* |
|
| 12/30/2010 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
| 12/02/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT A: 1) SWITCHED LIGHT FIXTURE REAR EXIT DOOR 2) PROVIDE STOOP EXIT DOOR 3) PROVIDE PROOF OF PERMIT REAR ADDITION WITH INSPECTIONS 4) COMPLETE KITCHEN SINK INSTALLATION UNIT B: 1) LABEL UNIT NUMBER 2) PROVIDE SWITCHED FIXTURE EXIT DOORS 3) WATER HEATER TPR VALVE TO GROUND. PROVIDE 1" CLEARANACE COMBUSTIBLES FROM B-VENT 4) COMPLETE KITCHEN SINK 5) BOTH UNITS: BEDROOM WINDOWS MUST BE OPERABLE FOR EMERGENCY EGRESS |
|
| 11/24/2010 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* UNIT B: 1) GROUNDED RECEPTS ON NON GROUNDED CIRCUITS 2) NEED GFI PROTECTION AT KITCHEN AND BATHROOM RECEPTS 3) MISSING COVER PLATES 4) OUTSIDE RECEPT TO BE FOR WET LOCATION 5) SUPPORT CONDUIT AT PANEL |