Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/28/2010 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 12/02/2010 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/16/2010 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ANSWR 867-2493 AT 10:00 AM 2) TPR LINE WATER HEATER MUST POINT DOWNWARD 6"-24" FROM GROUND 3) WATER HEATER LACKS REQUIRED SHUT OFF VALVE COLD WATER SUPPLY LINE 4) PROVIDE 1" CLEARANCE COMBUSTIBLES FROM B-VENT 5) ANTI-TILT STOVE 6) PROVIDE WORKING SMOKE DETECTORS 7) SEAL WATER CLOSET AT BASE 8) PROVIDE LISTED DEAD FRONT PANEL 9) REPLACE SHART POINT SCREW AT DEAD FRONT 10) LABEL CIRCUITS 11) REMOVE HASP FROM SERVICE PANEL |