Inspection History Details
Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/20/2011 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. VERIFY HEATING UNIT WORKS |
|
| 01/07/2011 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) FINISH #5, 8 & 9 |
|
| 12/01/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SMOKE DETECTORS NEEDED IN BEDROOMS-INSTALL PER INSTRUCTIONS 2) NO EGRESS IN BEDROOMS WITH WROUGHT IRON 3) FILL UNUSED OPENINGS IN PANEL 4) BREAKER NOT LISTED FOR USE BY MANUFACTURER 5) ONLY ONE GROUND CONDUCTOR PER TERMINAL LUG 6) SUPPORT RACEWAY ABOVE PANEL 7) EXPOSED NM CABLE MECH ROOM 8) MISSING FURNACE-WILL NEED PERMIT OR VERIFY ROOF UNIT 9) PLEASE VERIFY WATER HEATER PERMIT-UNIT DATE STAMPING 1/11/10 |
|
| 11/29/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1) LOCKED AND NO ACCESS |