Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) ACCESS REQUIRED |
|
| 11/08/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LEFT MESSAGE 9:45 AM 2) HAZARDOUS ELECTRICAL REAR PORCH 3) MISSING DEADFRONT AT SERVICE PANEL 4) ALL BREAKER TYPE MUST MATCH PANEL TYPE 5) PROVIDE ACCESS TO ROOF TOP TO INSPECT ADDED CIRCUITS 6) ALL BEDROOM SECURITY BARS IN BEDROOMS, ONE MUST OPERATE FREELY IN EACH ROOM WITHOUT USE OF SEPERATE TOOLS FOR EMERGENCY EGRESS 7) SMOKE ALARMS BEDROOMS AND HALLWAY 8) MANY ADDED CIRCUITS TO SUB PANEL LAUNDRY NOT TO CODE. HAVE QUALIFIED ELECTRICIAN REPAIR TO CODE 9) WATER HEATER TPR VALVE TO EXTERIOR 10) GFCI PROTECT KITCHEN COUNTER OUTLETS 11) REAR PORCH NOT TO CODE |