Permit: T10EL02506

Parcel: 140130830


Addresses:

1910 E WYOMING ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
12/06/2010 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
11/19/2010 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection :*
11/18/2010 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*

1. SECURE OMIT 30 AMP BREAKER WIRE UNDER SIZED. SEAL KNOCKOUTS PANEL.
2. ROOM TO ORGINAL PORCH NOTE 2
3. NOTE 3 FROM PRENOUS
4. SECURE DISHWASHER DRAIN HOUSE
11/02/2010 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE PROPER CLEARANCE IN FRONT OF PANEL FOR SERVICE
2) PROVIDE PROOF OF PERMIT AND INSPECTIONS OF REAR ADDITIONS NOT TO CODE
3) GAS LINE UNDER ROOF MUST BE RELOCATED
4) GFCI PROTECT EXTERIOR OUTLETS
5) HAVE QUALIFIED ELECTRICIAN CLEAN UP ALL WORK, NOT TO CODE AT PANEL
6) UNABLE TO LOCATE LOCK BOX FOR ENTRY