Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/03/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/02/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HOT AND GROUND IN BATH REVERSED 2) HOT AND NEUTRAL IN KITCHEN REVERSED |
|
| 10/22/2010 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |