Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2010 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) CORRECT THE T & P DISCHARGE LINE 2) COMPLETE GAS BOND |
|
| 10/04/2010 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED 2) MISSING WALL PLATES 3) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS 4) CEILING FANS CANNOT BE WIRED BY LAMP CORD. WIRE PER CODE OR REMOVE 5) BATHROOM RECEPTS TO BE GFI PROTECTED 6) SERVICE IS COMING LOOSE FROM BLDG STRUCTURE. NEEDS TO BE RE-SECURED 7) FLOOD LIGHT AT BACK OF HOUSE WIRE WITH LAMP CORD. WIRE PER CODE OR REMOVE 8) OUTDOOR RECEPTS TO BE GFI PROTECTED 9) RESCHEDULE WHEN 100 PERCENT COMPLETE |